Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.bc.uepb.edu.br/jspui/handle/tede/4824
Registro completo de metadados
Campo DCValorIdioma
dc.creatorFilgueira, Anna Kellssya Leite-
dc.creator.Latteshttp://lattes.cnpq.br/3362098815367188por
dc.contributor.advisor1Branco, Rodolfo Ramos Castelo-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3083529477144320por
dc.contributor.referee1Lopes, Andrei Guilherme-
dc.contributor.referee2Andrade Filho, Manoel Pereira de-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/9307675637592100por
dc.contributor.referee3Tomaz, Alecsandra Ferreira-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/6417757089917979por
dc.date.accessioned2023-11-29T11:42:43Z-
dc.date.available2999-12-31por
dc.date.issued2023-09-28-
dc.identifier.citationFILGUEIRA, Anna Kellssya Leite. Desenvolvimento e validação de um dispositivo para mobilização de tecidos moles com uso de tecnologias 3D. 2023. 73 f. Dissertação (Programa de Pós-Graduação Profissional em Ciência e Tecnologia em Saúde - PPGCTS) - Universidade Estadual da Paraíba, Campina Grande, 2024.por
dc.identifier.urihttp://tede.bc.uepb.edu.br/jspui/handle/tede/4824-
dc.description.resumoIntrodução: A mobilização de tecidos moles assistida por instrumentos (IASTM) é uma técnica terapêutica amplamente utilizada por profissionais de saúde para tratar distúrbios musculoesqueléticos. Visando atender a satisfação e bem-estar dos pacientes, novas tecnologias capazes de otimizarem a utilização de instrumentos únicos que se aplique a diferentes casos de tratamentos sem prejuízo a empunhadura e eficácia do resultado esperado são bem-vindas no segmento em questão. Objetivo: Desenvolver um projeto de dispositivo para mobilização de tecidos moles através do uso de tecnologias tridimensionais. Metodologia: Trata-se de uma pesquisa-ação de caráter exploratório com abordagem qualitativa, desenvolvida no laboratório de tecnologias tridimensionais (LT3D) do Núcleo de Tecnologias Estratégicas em Saúde (NUTES), alocado na Universidade Estadual da Paraíba (UEPB). Para cumprir os objetivos, o estudo perpassa por quatro etapas metodológicas: Levantamento Mercadológico e Literário; Projeto Conceptivo; Modelagem Virtual através da integração do CAD e CAE; Fabricação do dispositivo. Após a fabricação o dispositivo foi validado clinicamente. Resultados e Discussão: Foi desenvolvido um dispositivo único com superfície em arcos que formam curvaturas de tamanhos diferenciados. A simulação computacional atestou o dispositivo apto sem riscos de falhas. A análise clinica mostrou que o dispositivo é efetivo. Considerações Finais: O modelo em desenvolvimento é destinado para estimulação de tecidos superficiais, mobilização de tecidos profundos e quebra de tecido cicatricial, apresenta preferência por curvaturas de diferentes tamanhos em todo o desenho com variabilidade da superfície entre côncavo e convexo, com as pontas semelhantes a um gancho, favorecendo o encaixe anatômico ideal entre as mais variadas partes do corpo humano.por
dc.description.abstractIntroduction: Instrument-assisted soft tissue mobilization (IASTM) is a therapeutic technique widely used by healthcare professionals to treat musculoskeletal disorders. Aiming to meet patient satisfaction and well-being, new technologies capable of optimizing the use of unique instruments that apply to different treatment cases without compromising the grip and effectiveness of the expected result are welcome in the segment in question. Objective: Develop a device design for soft tissue mobilization through the use of three-dimensional technologies. Methodology: This is an exploratory action research with a qualitative approach, developed in the three-dimensional technologies laboratory (LT3D) of the Center for Strategic Health Technologies (NUTES), located at the State University of Paraíba (UEPB). To achieve the objectives, the study goes through four methodological stages: Marketing and Literary Survey; Conceptual Design; Virtual Modeling through the integration of CAD and CAE; Device manufacturing. After manufacturing, the device was clinically validated. Results and Discussion: A unique device was developed with an arched surface that forms curvatures of different sizes. The computer simulation confirmed that the device was suitable without any risk of failure. Clinical analysis showed that the device is effective. Final Considerations: The model under development is intended for stimulation of superficial tissues, mobilization of deep tissues and breakdown of scar tissue, with a preference for curvatures of different sizes throughout the design with surface variability between concave and convex, with tips similar to a hook, favoring the ideal anatomical fit between the most varied parts of the human body.por
dc.description.provenanceSubmitted by Anna Filgueira (anna.kellssya@aluno.uepb.edu.br) on 2023-11-14T13:47:24Z No. of bitstreams: 1 VERSÃO FINAL COMPLETA - ANNA KELLSSYA.pdf: 2681884 bytes, checksum: a88d67dc63a251e85968f2fbaf99b51a (MD5)eng
dc.description.provenanceRejected by Jean Medeiros (jeanletras@uepb.edu.br), reason: Bom dia, a sua submissão de dissertação nna BDTD da UEPB foi recusada pelos motivos abaixo: 1. A dissertação está com problemas de paginação. Faça o seguinte: a) A última página deve ser a 73, como você pediu na ficha catalográfica. Você pode adicionar páginas em branco numeradas ao final do TCC para alcançar o total desejado. 2. Além da dissertação, você precisa fazer o upload do Termo de Depósito (em anexo) em PDF preenchido e assinado pelo seu orientador e por você. Depois de corrigir estes problemas, basta você fazer uma nova submissão na BDTD. Grato pela atenção, Jean de Medeiros Azevedo Auxiliar de Biblioteca Biblioteca Central - UEPB on 2023-11-14T14:32:09Z (GMT)eng
dc.description.provenanceSubmitted by Anna Filgueira (anna.kellssya@aluno.uepb.edu.br) on 2023-11-19T15:34:07Z No. of bitstreams: 2 VERSÃO FINAL COMPLETA - ANNA KELLSSYA.pdf: 2683363 bytes, checksum: 98789589e41a7e2ffd9073762afcae14 (MD5) Identificação da tese ou dissertação.pdf: 374317 bytes, checksum: 904b6ebcb57c0ea6197f1c0c844e70b7 (MD5)eng
dc.description.provenanceApproved for entry into archive by Jean Medeiros (jeanletras@uepb.edu.br) on 2023-11-20T11:53:32Z (GMT) No. of bitstreams: 2 VERSÃO FINAL COMPLETA - ANNA KELLSSYA.pdf: 2683363 bytes, checksum: 98789589e41a7e2ffd9073762afcae14 (MD5) Identificação da tese ou dissertação.pdf: 374317 bytes, checksum: 904b6ebcb57c0ea6197f1c0c844e70b7 (MD5)eng
dc.description.provenanceMade available in DSpace on 2023-11-29T11:42:43Z (GMT). No. of bitstreams: 2 VERSÃO FINAL COMPLETA - ANNA KELLSSYA.pdf: 2683363 bytes, checksum: 98789589e41a7e2ffd9073762afcae14 (MD5) Identificação da tese ou dissertação.pdf: 374317 bytes, checksum: 904b6ebcb57c0ea6197f1c0c844e70b7 (MD5) Previous issue date: 2023-09-28eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Estadual da Paraíbapor
dc.publisher.departmentPró-Reitoria de Pós-Graduação e Pesquisa - PRPGPpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUEPBpor
dc.publisher.programPrograma de Pós-Graduação Profissional em Ciência e Tecnologia em Saúde - PPGCTSpor
dc.rightsAcesso Embargadopor
dc.subjectTecidos Molespor
dc.subjectMobilizaçãopor
dc.subjectImpressão 3Dpor
dc.subject.cnpqCIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONALpor
dc.subject.cnpqENGENHARIA MECANICA::PROCESSOS DE FABRICACAOpor
dc.subject.cnpqENGENHARIA DO PRODUTO::DESENVOLVIMENTO DE PRODUTOpor
dc.titleDesenvolvimento e validação de um dispositivo para mobilização de tecidos moles com uso de tecnologias 3Dpor
dc.title.alternativeDevelopment and validation of a device for soft tissue mobilization using 3D technologieseng
dc.typeDissertaçãopor
Aparece nas coleções:PPGCTS - Dissertações

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DS - Anna Kellssya Leite FilgueiraDS - Anna Kellssya Leite Filgueira2.62 MBAdobe PDFBaixar/Abrir Pré-Visualizar    Solictar uma cópia
Termo de Depósito BDTDTermo de Depósito BDTD365.54 kBAdobe PDFBaixar/Abrir Pré-Visualizar    Solictar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.