Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.bc.uepb.edu.br/jspui/handle/tede/5261
Tipo do documento: Tese
Título: Análise comparativa entre softwares termográficos na aquisição da temperatura facial
Autor: França, Kalinne Pereira de
Primeiro orientador: Bento, Patrícia Meira
Primeiro membro da banca: Barbosa, Jussara da Silva
Segundo membro da banca: Alves, Pollianna Muniz
Terceiro membro da banca: Melo, Daniela Pita de
Quarto membro da banca: Amorim, Ana Marly Araujo Maia
Resumo: Esta pesquisa teve como objetivo comparar os dados térmicos obtidos na face a partir dos softwares termográficos FLIR Tools®, FLIR Thermal Studio® e VisionFy® e verificar a diferença de temperatura entre imagens termográficas faciais obtidas com e sem nicho de isolamento térmico analisadas pelo FLIR Thermal Studio®. É um estudo do tipo transversal, analítico, observacional e quantitativo, realizado no Laboratório de Termografia Infravermelha do Departamento de Odontologia, Campus I, da Universidade Estadual da Paraíba – UEPB. Para as aquisições térmicas foi utilizada uma câmera térmica de sensor infravermelho FLIR, modelo T650SC Infrared, com a finalidade de comparar os 3 softwares e foram escolhidas 6 regiões bilaterais na face: comissura palpebral lateral, sulco nasolabial e comissura labial. Para avaliar a influência do nicho de isolamento, foi utilizado um dispositivo com placas de poliestireno expandido (EPS - isopor), revestido interna e externamente com papel alumínio e etileno acetato de vinila (EVA). A análise da influência do isolamento térmico foi realizada na região das comissuras palpebrais laterais. As análises estatísticas foram realizadas no software Jamovi (v. 2.5). A normalidade dos dados foi verificada pelo teste de Shapiro-Wilk e estes foram apresentados como mediana e intervalo interquartílico. As comparações entre softwares foram realizadas pelo teste de Friedman, seguido do post-hoc de Durbin-Conover e para avaliar o efeito do nicho de isolamento térmico utilizou-se o teste de Wilcoxon. O nível de significância adotado foi de 5%. As aferições termográficas evidenciaram que o uso do nicho de isolamento térmico apresentou aumento estatisticamente significativo da temperatura na comissura palpebral lateral direita. No lado esquerdo, não houve diferença significativa. Na comparação entre os softwares, observaram-se variações nos valores de temperatura mínima e máxima, com o VisionFy® apresentando temperaturas mínimas mais altas e máximas ligeiramente mais baixas em todas as ROIs. Além disso, o software VisionFy® registrou valores medianos mais elevados nas regiões de comissura palpebral lateral esquerda, sulcos nasolabiais e comissura labial esquerda, mantendo consistência com os demais softwares na comissura palpebral direita. Conclui-se que os achados desta pesquisa demonstram que tanto a escolha do software de análise quanto o uso do nicho de isolamento térmico influenciam significativamente nos resultados das medições termográficas faciais.
Abstract: This study aimed to compare thermal data obtained on the face using FLIR Tools®, FLIR Thermal Studio®, and VisionFy® thermographic software and to assess the temperature difference between facial thermographic images obtained with and without a thermal insulation niche, analyzed by FLIR Thermal Studio®. This is a cross-sectional, analytical, observational, and quantitative study conducted at the Infrared Thermography Laboratory of the Department of Dentistry, Campus I, of the State University of Paraíba (UEPB). A FLIR T650SC Infrared thermal camera with an infrared sensor was used for thermal acquisition to compare the three software programs. Six bilateral facial regions were selected: lateral palpebral commissure, nasolabial fold, and labial commissure. To evaluate the influence of the insulation niche, a device with expanded polystyrene (EPS) plates coated internally and externally with aluminum foil and ethylene vinyl acetate (EVA) was used. The analysis of the influence of thermal insulation was performed in the region of the lateral palpebral commissures. Statistical analyses were performed using Jamovi software (v. 2.5). Data normality was verified by the Shapiro-Wilk test, and these were presented as median and interquartile range. Comparisons between software programs were performed using the Friedman test, followed by the Durbin-Conover post-hoc test, and the Wilcoxon test was used to assess the effect of the thermal insulation niche. The significance level adopted was 5%. Thermographic measurements showed that the use of the thermal insulation niche resulted in a statistically significant increase in temperature in the right lateral palpebral commissure. On the left side, there was no significant difference. The comparison between the software programs showed variations in minimum and maximum temperature values, with VisionFy® presenting higher minimum and slightly lower maximum temperatures in all ROIs. Furthermore, the VisionFy® software recorded higher median values in the left lateral palpebral commissure, nasolabial folds, and left labial commissure, consistent with the other software programs in the right palpebral commissure. The findings of this study demonstrate that both the choice of analysis software and the use of a thermal insulation niche significantly influence the results of facial thermographic measurements.
Palavras-chave: Termografia
Software
Temperatura
Área(s) do CNPq: CIENCIAS DA SAUDE::ODONTOLOGIA
Idioma: por
País: Brasil
Instituição: Universidade Estadual da Paraíba
Sigla da instituição: UEPB
Departamento: Centro de Ciências Biológicas e da Saúde - CCBS
Programa: Programa de Pós-Graduação em Odontologia - PPGO
Citação: FRANÇA, Kalinne Pereira de. Análise comparativa entre softwares termográficos na aquisição da temperatura facial. 2025. 103 f. Tese (Doutorado em Odontologia) - Universidade Estadual da Paraíba, Campina Grande, 2025.
Tipo de acesso: Acesso Embargado
URI: http://tede.bc.uepb.edu.br/jspui/handle/tede/5261
Data de defesa: 2-Jun-2025
Aparece nas coleções:PPGO - Teses

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
TS - Kalinne Pereira de França.pdfTS - Kalinne Pereira de França2.3 MBAdobe PDFBaixar/Abrir Pré-Visualizar    Solictar uma cópia
Termo de Depósito BDTD.pdfTermo de Depósito BDTD146.07 kBAdobe PDFBaixar/Abrir Pré-Visualizar    Solictar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.