Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.bc.uepb.edu.br/jspui/handle/tede/4846
Tipo do documento: Tese
Título: Avaliação termográfica da região temporomandibular e a sua correlação com a hipervigilãncia da dor e a qualidade do sono
Autor: Souza Junior, Erasmo Freitas de 
Primeiro orientador: Bento, Patrícia Meira
Primeiro membro da banca: Bento, Patrícia Meira
Segundo membro da banca: Targino, Ramon Firmino
Terceiro membro da banca: Arruda, Maria Jacinta Arêa Leão Lopes Araújo
Quarto membro da banca: Catão, Maria Helena Chaves de Vasconcelos
Quinto membro da banca: Melo, Daniela Pita de
Resumo: Objetivo: Verificar se a Hipervigilância da Dor (HD) e a Qualidade do Sono (QS) são variáveis de confusão no exame de termografia infravermelha (TI) da articulação temporomandibular (ATM) e dos músculos temporal e masseter. Metodologia: Foi realizado um estudo transversal e analítico, contando com uma amostra composta de 80 participantes sem Disfunções Temporomandibulares (DTM’s) e 40 participantes com DTMs. Foram coletados dados da HD e da QS dos participantes sem DTM’s e realizadas TI na articulação temporomandibular e músculos masseter e temporal dos participantes com e sem DTMs. Para a triagem e seleção dos participantes que não apresentaram DTM’s foi aplicada o questionário TMD Pain Screener, com a aplicação do Diagnostic Criteria for Temporomandibular Disorders naqueles com a referida disfunção. A QS foi verificada por meio dos do Pittsburgh Sleep Quality Index (PSQI). Já a averiguação da HD foi feita por meio do Pain Vigilance and Awareness Questionnaire (PVAQ). As termografias infravermelhas foram realizadas em laboratório apropriado utilizando uma câmera portátil de sensor infravermelho FLIR, modelo T650 Infrared e o software FLIR ResearchIR Max para a análise destas. A análise estatística ocorreu por meio das correlações entre as temperaturas das áreas de interesse com os resultados do PVAQ e do PSQI e por meio das comparações das temperaturas das áreas de interesse entre os participantes com e sem DTM’s, onde o grupo sem DTM’s foi subdivido, tanto de acordo com a qualidade do sono, quanto pelo nível de hipervigilância da dor. O intervalo de confiança para todos os testes foi de 95%, utilizado um nível de significância fixado em 5%. Resultados: Dentre os participantes avaliados, não foram encontradas correlações significativas entre a QS e as temperaturas das áreas de interesse (p>0,05). Quanto à HD foi encontrada uma correlação positiva fraca, mas estatisticamente significante com as assimetrias das temperaturas do músculo temporal tanto nos em relação ao valor adimensional (ρ=0,289) quanto não adimensional (ρ=0,223). Nas comparações das temperaturas dos participantes sem DTM’s controlado pela HD e pela QS com os participantes com DTM’s, a média dos valores bilaterais absolutos apresentou diferenças nas áreas dos músculos temporal e de masseter, independentemente do grau de HD e QS dos participantes sem DTM’s (p<0,05), com maior valor de temperatura para os pacientes com DTM. Na média dos valores bilaterais absolutos ATM, nos valores adimensionais das médias dos valores bilaterais nos terços superior e inferior do masseter e nas médias dos valores de assimetria adimensional do músculo temporal, as diferenças entre participantes com e sem DTM’s se distinguiram de acordo com a HD dos participantes sem DTM’s (p<0,05). Os valores bilaterais absolutos da ATM e adimensionais das médias dos valores bilaterais do masseter também apresentaram diferenças de acordo com a QS dos participantes sem DTM’s (p<0,05). Os participantes com DTM’s apresentaram valores de temperaturas maiores do que os participantes sem DTM’s em todas as comparações com diferenças estatisticamente significantes. Conclusão: A HD e a QS podem ser consideradas variáveis de confusão no exame de termografia infravermelha da ATM e dos músculos temporal e masseter.
Abstract: Objective: Verify whether Hypervigilance to Pain (HP) and Sleep Quality (SQ) are confounding variables in the infrared thermography (IT) examination of the temporomandibular joint (TMJ) and temporal and masseter muscles. Methodology: A cross-sectional and analytical study was conducted, with a sample of 80 participants without Temporomandibular Disorders (TMD) and 40 participants with TMD. H P and SQ data were collected from participants without TMD and IT was performed on the temporomandibular joint and masseter and temporal muscles of participants with and without TMDs. For the screening and selection of participants who did not show TMD, the TMD Pain Screener questionnaire was applied, with the application of the Diagnostic Criteria for Temporomandibular Disorders in those with the referred dysfunction. The SQ was verified using the Pittsburgh Sleep Quality Index (PSQI). And the HP assessment was done through the Pain Vigilance and Awareness Questionnaire (PVAQ). Infrared thermography was performed in an appropriate laboratory using a portable FLIR infrared sensor camera, model T650 Infrared, and the FLIR ResearchIR Max software for their analysis. The statistical analysis was performed by means of correlations between the temperatures of the areas of interest and the results of the PVAQ and PSQI and by comparing the temperatures of the areas of interest between the participants with and without TMD, where the group without TMD was subdivided, both according to the sleep quality and the level of hypervigilance to pain. The confidence interval for all tests was 95%, using a significance level set at 5%. Results: Among the evaluated participants, no significant correlations were found between SQ and the temperatures of the areas of interest (p>0.05). Regarding HP, a weak but statistically significant positive correlation was found with the asymmetries of temporal muscle temperatures, both regarding the dimensionless (ρ=0.289) and non-dimensionless (ρ=0.223) values. In the comparisons of the temperatures of the participants without TMD controlled by HP and SQ with the participants with TMD, the mean of the absolute bilateral values showed differences in the areas of the temporal and masseter muscles, regardless of the degree of HP and SQ degree of the participants without TMD (p<0.05), with a higher temperature value for patients with TMD. In the mean of the absolute bilateral TMJ values, in the dimensionless values of the bilateral values means in the upper and lower thirds of the masseter, and in the means of the dimensionless asymmetry values of the temporal muscle, the differences between participants with and without TMD were distinguished according to the HP of the participants without TMD (p<0.05). The absolute bilateral values of TMJ and the dimensionless mean bilateral values of the masseter also showed differences according to the SQ of the participants without TMD (p<0.05). Participants with TMD showed higher temperature values than participants without TMD in all comparisons with statistically significant differences. Conclusion: HP and SQ can be considered confounding variables in infrared thermography examination for TMJ and temporal and masseter muscles.
Palavras-chave: Qualidade do sono
Articulação temporomandibular
Termografia
Área(s) do CNPq: CIENCIAS DA SAUDE::ODONTOLOGIA
Idioma: por
País: Brasil
Instituição: Universidade Estadual da Paraíba
Sigla da instituição: UEPB
Departamento: Pró-Reitoria de Pós-Graduação e Pesquisa - PRPGP
Programa: Programa de Pós-Graduação em Odontologia - PPGO
Citação: SOUZA JUNIOR, Erasmo Freitas de. Avaliação termográfica da região temporomandibular e a sua correlação com a hipervigilância da dor e a qualidade do sono. 2023. 121 f. Tese (Programa de Pós-Graduação em Odontologia - PPGO) - Universidade Estadual da Paraíba, Campina Grande, 2024.
Tipo de acesso: Acesso Embargado
URI: http://tede.bc.uepb.edu.br/jspui/handle/tede/4846
Data de defesa: 10-Nov-2023
Aparece nas coleções:PPGO - Teses

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
TS – Erasmo Freitas de Souza Junior.pdfTS – Erasmo Freitas de Souza Junior4.09 MBAdobe PDFBaixar/Abrir Pré-Visualizar    Solictar uma cópia
Termo de Depósito BDTD.pdfTermo de Depósito BDTD284.6 kBAdobe PDFBaixar/Abrir Pré-Visualizar    Solictar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.