Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.bc.uepb.edu.br/jspui/handle/tede/3367
Registro completo de metadados
Campo DCValorIdioma
dc.creatorBarbosa, Amanda da Silva-
dc.creator.Latteshttp://lattes.cnpq.br/9017442680465381por
dc.contributor.advisor1Ceballos, Beatriz Susana Ovruski de-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9321950498637802por
dc.contributor.advisor-co1Lopes, Wilton Silva-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/1493216651945826por
dc.contributor.referee1Barros, Aldre Jorge Morais-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/5354975426596167por
dc.contributor.referee2Leite, Valderi Duarte-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/2319382787465258por
dc.date.accessioned2019-05-31T14:16:55Z-
dc.date.issued2018-05-30-
dc.identifier.citationBARBOSA, A. da S. Remoção de Microcystis aeruginosa e microcistina-LR de águas superficiais com uso de filtro doméstico seguido de processo oxidativo avançado (UV/H2O2). 2018. 71f. Dissertação (Programa de Pós-Graduação em Ciência e Tecnologia Ambiental - PPGCTA) - Universidade Estadual da Paraíba, Campina Grande, 2018.por
dc.identifier.urihttp://tede.bc.uepb.edu.br/jspui/handle/tede/3367-
dc.description.resumoA presença de cianobactérias produtora e cianotoxinas tem efeitos negativo nos corpos hídricos em particular nos destinados ao abastecimento público devido ao efeito nocivo dessas substâncias à saúde humana e de animais. Em geral as cianotoxinas não são removidas pelas tecnologias convencionais de potabilização de água, fato alarmante, visto que muitas pessoas, principalmente de comunidades rurais fazem uso da água sem nenhum tratamento prévio. O presente trabalho buscou avaliar a eficiência de remoção de células de Microcystis aeruginosa e da toxina microcistina-LR (MC-LR) de um sistema constituído por dois sistemas de filtros domésticos com dois tipos diferentes de elementos filtrantes: F1- com velas compostas de camadas sucessivas de Caulim, filito, PVC composto, resinas termoplásticas, apresentando parede microporosa com poros de 1,0 μm e o F2- com velas compostas de camadas sucessivas de Caulim, Filito, Prata coloidal, Carbono ativado, Aço inox, PVC, Hot Melt, apresentando parede microporosa com poros de 0,5 μm, seguido por reator fotocatalítico (UV/H2O2). A pesquisa foi conduzida em três etapas: I: coleta de água bruta (AB) no reservatório Saulo Maia; cultivo de cálulas de M. aeruginosa II: preparação da água de estudo (AE) que consistiu na adição de cultivo de células lisadas de M. aeruginosa na AB previamente coletada (AB). Em seguida foram realizadas as filtrações de AE pelo sistema F1 e pelo F2; III: aplicação, nos efluentes de F1 (AEF1) e de F2 (AEF2), de processo oxidativo avançado (POA - UV/H2O2) utilizando um reator fotocatalítico. Foram realizados 6 ensaios, para cada efluente dos filtros domésticos, com diferentes dosagens de H2O2 (5, 25, 50, 100, 500, 1000 Mm) e tempos em AEF1 e AEF2 de 1, 2,5, 5, 15, 30, 45 e 60 minutos. Os resultados mostraram que a filtração, em ambos os filtros (F1 e F2) foi eficiente na remoção de cor (100%), turbidez (99%) e fosfato (40%). As águas filtradas provenientes de F2 apresentaram redução de 68% de células de M. aeruginosa e de XX 46% os de F1. Não foi satisfatória a remoção de MC-LR durante a filtração pelos dois tipos de velas: Os valores residuais foram de 1,9 µg/L em AEF1 e de 1,7 µg/L em AEF2. Aplicando-se POA (H2O2 /UV), a melhor dosagem de H2O2 no AEF1 foi 500 mM para o tempo de oxidação de 60 minutos, condições que permitiram atingir a menor concentração de MC-LR nesse efluente (de 0,98 µg/L) pós tratamento oxidativo. No entanto, nessas condições, os valores de turbidez foram superiores ao valor máximo permitido pela portaria de consolidação 05/2017 do Ministério da Saúde anexo XX de 1,0 uT, enquanto que para os efluente AEF2 a menor concentração de MC-LR (de 0,6 µg/L ) foi obtida com a dosagem de 1.000 mM de H2O2 e tempo de oxidação de 60 minutos. O sistema de tratamento proposto, de filtração por filtros domésticos seguidos da aplicação de POA (UV/H2O2) mostra-se altamente eficientes na eliminação de M. aeruginosa e da toxina MC-LR, independente do tipo do meio filtrante uitlizado .por
dc.description.abstractThe presence of productive cyanobacteria and cyanotoxins has a negative effect on water in particular in food for the absorption of human and human energy. In general, cyanotoxins are not removed by water energy waves, alarming fact, as people are warmer, water currents are not treated. The present study aimed to evaluate the efficiency of the removal of Microcystis aeruginosa and Microcystin-LR (MC-LR) cells from a system consisting of two filtration systems of two different types of filter elements: F1- with candles composed of successive layers of Kaolin, phyllite, composite PVC, thermoplastic resins, microporous wall collection with 1.0 μm pores and F2- with candles composed of successions of Kaolin, Filito, Colloidal Silver, Activated Carbon, Stainless Steel, PVC, Hot Melt, microporous wall with 0.5 μm pores, followed by photocatalytic reactor (UV / H2O2). The research was carried out in three stages: I: raw water (AB) collection in the Saulo Maia reservoir; Calculation of M. aeruginosa II cells: study water preparation (AE) which consisted of the supplementation of lysed cells of M. aeruginosa in AB. In a following were then the AE filtrations by the F1 system and F2; III: application of advanced oxidative process (POA - UV / H2O2) to the effluents of F1 (AEF1) and F2 (AEF2) using a photocatalytic reactor. Six assays were carried out for each domestic filter effluent with different dosages of H2O2 (5, 25, 50, 100, 500, 1000 Mm) and AEF1 and AEF2 times of 1, 2,5, 5, 15, 30, 45 and 60 minutes. The results of the filtration in both filters (F1 and F2) were efficient in the removal of color (100%), turbidity (99%) and phosphate (40%). As the filtered molecules from F2 decreased from 68% of M. aeruginosa cells to 46% from those of F1. Residual values were 1.9 μg / L in AEF1 and 1.7 μg / L in AEF2. The use of POA (H2O2 / UV), a better dosage of H2O2 in AEF1 was 500 mM for the oxidation time of 60 minutes, allowing a lower concentration of MC-LR in this effluent (0.98 μg / L) after oxidative treatment. However, turbidity values are higher than 1.0%, while for AEF2 effluents and lower concentration of MC-LR (0.6 μg / L) was obtained with a dosage of 1000 mM H2O2 and oxidation of 60 minutes. The proposed treatment system for adhesive adsorption filtration is indicated for the application of PAM (UV / H2O2) and is effective in the elimination of M. aeruginosa and MC-LR toxin, regardless of the type of media used.eng
dc.description.provenanceSubmitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2019-05-31T14:16:55Z No. of bitstreams: 1 PDF - Amanda da Silva Barbosa.pdf: 29593151 bytes, checksum: 2cf2d26f81c7519f07f5a833a38c384a (MD5)eng
dc.description.provenanceMade available in DSpace on 2019-05-31T14:16:55Z (GMT). No. of bitstreams: 1 PDF - Amanda da Silva Barbosa.pdf: 29593151 bytes, checksum: 2cf2d26f81c7519f07f5a833a38c384a (MD5) Previous issue date: 2018-05-30eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://tede.bc.uepb.edu.br/jspui/retrieve/8368/PDF%20-%20Amanda%20da%20Silva%20Barbosa.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade Estadual da Paraíbapor
dc.publisher.departmentPró-Reitoria de Pós-Graduação e Pesquisa - PRPGPpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUEPBpor
dc.publisher.programPrograma de Pós-Graduação em Ciência e Tecnologia Ambiental - PPGCTApor
dc.rightsAcesso Abertopor
dc.subjectProcesso Oxidativo Avançadopor
dc.subjectMicrocistina-LRpor
dc.subjectCianobactériaspor
dc.subjectMicrocystin-LReng
dc.subjectAdvanced Oxidative Processeng
dc.subjectMicrocystis aeruginosaeng
dc.subjectMicrocystis aeruginosapor
dc.subject.cnpqENGENHARIAS::ENGENHARIA SANITARIApor
dc.titleRemoção de Microcystis aeruginosa e microcistina-LR de águas superficiais com uso de filtro doméstico seguido de processo oxidativo avançado (UV/H2O2)por
dc.typeDissertaçãopor
Aparece nas coleções:PPGCTA - Dissertações

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
PDF - Amanda da Silva Barbosa.pdfPDF - Amanda da Silva Barbosa28.9 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.