Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.bc.uepb.edu.br/jspui/handle/tede/2675
Registro completo de metadados
Campo DCValorIdioma
dc.creatorAbílio, Vanessa Maria Freire-
dc.creator.Latteshttp://lattes.cnpq.br/3813670296581629por
dc.contributor.advisor1Bento, Patrícia Meira-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/7371238765825611por
dc.contributor.referee1Santos, Rosenês Lima dos-
dc.contributor.referee2Melo, Daniela Pita de-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/2824485698432887por
dc.date.accessioned2016-11-16T14:20:54Z-
dc.date.issued2013-07-15-
dc.identifier.citationABÍLIO, V. M. F. Análise comparativa entre dois sistemas digitais frente à radiopacidade de materiais dentários. 2013. 102f. Dissertação (Programa de Pós-Graduação em Odontologia - PPGO) - Universidade Estadual da Paraíba, Campina Grande, 2013.por
dc.identifier.urihttp://tede.bc.uepb.edu.br/tede/jspui/handle/tede/2675-
dc.description.resumoA imagem digital representa um grande avanço na Radiologia Odontológica, uma vez que constitui um método rápido de obtenção de imagem e de fácil avaliação. O objetivo deste trabalho foi comparar o sistema digital semi-direto utilizando o Digora Optime® com o sistema digital indireto que utilizou câmera digital de CCD, frente à radiopacidade dos materiais dentários indicados para base ou forramento, bem como verificar a influência da variação de tempo de exposição e da distância foco- filme no grau de radiopacidade apresentado por estes materiais. Foram confeccionados 10 corpos-de prova (4 X 2 mm) para cada marca de material dentário utilizada (KetacTM Molar Easymix, Vidrion F, GC Fugi LiningTM LC, VitrebondTM, tetricMR Z350 XT Flow e Tetric® N Flow), totalizando 60 espécimes, usando uma matriz acrílica. Os corpos-de-prova foram radiografados junto a uma escala de alumínio e secções transversais de dentes com 2mm, por ambos os sistemas digitais em quatro combinações de tempo de exposição/distância foco-filme diferentes(0,12s/20cm; 0,12s/40cm; 0,25s/20cm e 0,25s/40cm). A radiopacidade das estruturas radiografadas foram mensuradas utilizando a função analyse histogram do programa Image J. O dados foram analisados por meio da estatística descritiva e através dos testes não- paramétrico de Wilcoxon-Mann Whitney e teste T de Sudent. Apenas o Vidrion F apresentou radiopacidade inferior a dentina e ao degrau de 2mm do penetrômetro, sendo esta diferença significativa (p<0,05), para todas as situações utilizando o sistema digital semi-direto e, para algumas situações, utilizando o sistema digital indireto. As médias de radiopacidade para todos os materiais estudados foram significativamente maiores (p<0,05) quando foi utilizado o sistema digital semi-direto (Digora Optime®). Houve diferença significativa (p<0,05) na radiopacidade dos materiais, exceto para o Vidrion F, quando ocorreu variação no tempo de exposição, bem como quando ocorreu variação na distância foco-filme. Conclui-se que o sistema digital semi-direto (Digora optime®) mostrou ser mais preciso para as medições de radiopacidade quando comparado ao sistema digital indireto, sendo nesta situação mais indicado para ser utilizado clinicamente como método auxiliar de diagnóstico.por
dc.description.abstractDigital image is a breakthrough in dental radiology characterized by being a quick and easy method of obtaining and evaluating of images. The aim of this study was to compare the semi-direct digital system (Digora Optime®) with the indirect digital system (CCD digital camera) in relation to radiopacity of dental materials indicated as base or liner. In addition, it was proposed to verify the influence of different exposure times and focus-film distances on the degree of radiopacity shown by these materials. A total of 10 specimens (4 X 2 mm) were made for each brand of restorative material employed (KetacTM Molar Easymix, Vidrion F, GC Fugi LiningTM LC, VitrebondTM, FiltekMR Z350 XT Flow and Tetric® N Flow), total of 60 specimens, by using an acrylic matrix. The specimens were radiographed together with an aluminum scale and cross-sections of teeth with 2 mm by both digital systems in four combinations of exposure time / different focus-film distances (0.12 s / 20 cm; 0.12 s /40 cm, 0.25 s /20 cm, 0.25 s /40 cm). The radiopacity of radiographed structures was measured using the tool “analyze histogram” on the software Image J. Data were analyzed using descriptive statistics and non-parametric tests: Wilcoxon, Mann- Whitney and Student’s t test. Only Vidrion F showed radiopacity lower than that of dentin and 2-mm cross-sections with statistically significant difference (p < 0.05) for all cases using the semi-direct digital system and for some cases using the indirect digital system. The radiopacity means for all materials studied were significantly higher (p <0.05) when the semi-direct digital system (Digora Optime®) was used. There was significant difference (p <0.05) in the radiopacity of the materials – except for Vidrion F – when exposure time and focus-film distance changed. It was concluded that the semi-direct digital system (Digora optime®) was more precise for measuring radiopacity compared to the indirect digital system. Thus, the semi-direct procedure is indicated to be used clinically as an auxiliary diagnostic method.eng
dc.description.provenanceSubmitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2016-10-26T11:47:13Z No. of bitstreams: 1 PDF - Vanessa Maria Freire Abílio.pdf: 2920508 bytes, checksum: 9dd2d9baca2d37200df8d4240c629561 (MD5)eng
dc.description.provenanceApproved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2016-11-16T14:20:54Z (GMT) No. of bitstreams: 1 PDF - Vanessa Maria Freire Abílio.pdf: 2920508 bytes, checksum: 9dd2d9baca2d37200df8d4240c629561 (MD5)eng
dc.description.provenanceMade available in DSpace on 2016-11-16T14:20:54Z (GMT). No. of bitstreams: 1 PDF - Vanessa Maria Freire Abílio.pdf: 2920508 bytes, checksum: 9dd2d9baca2d37200df8d4240c629561 (MD5) Previous issue date: 2013-07-15eng
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://tede.bc.uepb.edu.br/jspui/retrieve/5764/PDF%20-%20Vanessa%20Maria%20Freire%20Ab%c3%adlio.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade Estadual da Paraíbapor
dc.publisher.departmentPró-Reitoria de Pós-Graduação e Pesquisa - PRPGPpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUEPBpor
dc.publisher.programPrograma de Pós-Graduação em Odontologia - PPGOpor
dc.rightsAcesso Abertopor
dc.subjectMateriais dentáriospor
dc.subjectRadiografia dentáriapor
dc.subjectRadiografia dentária digitalpor
dc.subjectCimentos dentáriospor
dc.subjectCimento de ionômero de vidropor
dc.subjectGlass ionomer cementseng
dc.subjectDental materialseng
dc.subjectDental radiographyeng
dc.subjectDigital dental radiographyeng
dc.subject.cnpqCIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleAnálise comparativa entre dois sistemas digitais frente à radiopacidade de materiais dentáriospor
dc.title.alternativeComparative analysis between two digital systems for analyzing radiopacity of restorative materialseng
dc.typeDissertaçãopor
Aparece nas coleções:PPGO - Dissertações

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
PDF - Vanessa Maria Freire Abílio.pdfPDF - Vanessa Maria Freire Abílio2.85 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.