Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.bc.uepb.edu.br/jspui/handle/tede/4775
Tipo do documento: Tese
Título: Desenvolvimento de um afastador labial para uso em exame termográfico da cavidade bucal
Título(s) alternativo(s): Design of a cheek and lip retractor for intraoral in thermographic image acquisition
Autor: Lopes, Layrlla Kateriny Moura Oliveira 
Primeiro orientador: Melo, Daniela Pita de
Primeiro coorientador: Castelo Branco, Rodolfo Ramos
Primeiro membro da banca: Pontual, Andréa dos Anjos
Segundo membro da banca: Silva, Paulo César Sales da
Terceiro membro da banca: Bento, Patrícia Meira
Quarto membro da banca: Costa, Edja Maria Melo de Brito
Quinto membro da banca: Melo, Daniela Pita de
Resumo: O objetivo deste estudo foi investigar a influência de três afastadores labiais na aferição de temperatura de imagens de temografia infravermelha (TI) intraoral, bem como desenvolver, por meio de manufatura aditiva (MA), um modelo de afastador bucal a ser empregado no exame de TI. Foram realizadas imagens TI intraorais em 30 voluntários usando três afastadores, sendo dois convencionais, o Afastador Flex (AF) e o Afastador Lateral em U (AU), e um Afastador Flex Adaptado com isopor (AFA) para simular um aparato bloqueador de correntes de ar da respiração. Foram realizadas três aquisições para cada afastador, variando-se o valor de emissividade (Ɛ) (0,98, 0,96 e 0,91). Para obtenção das imagens, utilizou-se a câmera térmica FLIR modelo T650sc Infrared posicionada a 40cm do voluntário. A temperatura média das regiões de interesse (ROI) dos dentes anteriores superiores foram registradas para posterior comparação. A partir dos resultados encontrados, construiu-se um afastador com um aparato central, utilizando o ciclo digital de fabricação, através de ferramentas computacionais Computer Aided Design (CAD), Computer Aided Engineering (CAE), Computer Aided Manufacturing (CAM) e impressão 3D, por meio da tecnologia Fused Deposition Modeling (FDM) utilizando o material Acrilonitrila Butadieno Estireno (ABS). Em seguida, realizou-se aquisições térmicas em 10 voluntários, com registro da temperatura média das ROIs dos dentes anteriores superiores. Um questionário com diferentes métodos de Escala Visual Analógica (EVA) foi aplicado para avaliar o grau de desconforto do dispositivo criado. Para análise estatística, foram utilizados testes paramétricos ANOVA two-way, teste T e o teste ANOVA de Friedman. Maiores médias de temperatura foram encontradoas no dente 12 (30,42ºC), com AU na Ɛ 0,91. Os valores de temperatura obtidos com o afastador AU diferiram estatisticamente dos demais afastadores (p<0,05). Os valores de temperatura obtidos utilizando Ɛ0,91 diferiram estatisticamente dos obtidos utilizando Ɛ0,98 e 0,96 para todos os tipos de afastadores. O dispositivo desenvolvido possui características de resistência ao processo e ao tipo de material, conforme o CAE. Os valores de temperatura obtidos com o afastador desenvolvido foram inferiores em relação ao dispositivo AU, com diferença estatisticamente significativa (p<0,05). Quanto ao grau de desconforto, a maioria dos pacientes o classificou como leve, sem diferença estatisticamente significativa entre os métodos da escala de aferição de dor avaliados (p>0,05). Afastadores convencionais utilizados na aquisição de imagens térmicas podem interferir na precisão do valor de temperatura obtido. O desenvolvimento de um afastador com anteparo central é necessário para adquirir dados confiáveis de temperatura, assim a MA é capaz de facilitar fabricação de peças que solucionam problemas clínicos, além de permitir melhor adaptação do dispositivo a cavidade oral.
Abstract: The aim of this study, therefore, is to investigate the influence of three lip retractors and three different emissivity values on the temperature measurement of intraoral IT images, as well as to develop, through Additive Manufacturing (AM), a model of mouth retractor to be used in the exam. Intraoral Infreared Thermography (IT) images were taken in 30 volunteers with two conventional retractors, Flex Retractor (FR) and Lateral U-shaped Retractor (UR), and a Flex Retractor Adapted with Styrofoam (FRadapt) to simulate a draft blocking device of breathing. Three acquisitions were performed for each retractor, varying the emissivity value (Ɛ) (0.98, 0.96 and 0.91). For obtaining thermal images, a FLIR thermal camera model T650sc Infrared was used, positioned 40cm from the volunteer and the average temperature of the regions of interest (ROI) of the upper anterior teeth were recorded for later comparison. A retractor was built with a central apparatus, using the digital manufacturing cycle, through computational tools Computer Aided Design (CAD), Computer Aided Engineering (CAE), Computer Aided Manufacturing (CAM) and 3D printing, through Fused Deposition Modeling (FDM) technology using acrylonitrile butadiene styrene (ABS) material. Then, thermal acquisitions were performed in 10 volunteers, comparing the developed device with the UA. Mean temperature values of the same ROIs evaluated on axis 1 were obtained for later comparison. In addition, a questionnaire with different methods of Visual Analog Scale (VAS) was applied to assess the degree of discomfort of the created device. For statistical analysis, two-way ANOVA parametric tests, t test and Friedman's ANOVA test were used. Was observed higher temperature mean values for tooth 12 (30.42ºC), with UA at Ɛ 0.91. The mena temperature values obtained with the UR retractor differed statistically from the other assessed retractors (p<0.05). The temperature values obtained using Ɛ0.91 differed statistically from those obtained using Ɛ0.98 and 0.96 for all types of retractors. The CAE result demonstrated that the device has similar characteristics of resistance to the process and to the type of material. When comparing the temperature values obtained with the retractor developed in the study with the UR, we observed statistically significant difference (p<0.05), with the highest mean temperature obtained for the UR. As for the degree of discomfort, most patients classified it as mild, with no statistically significant difference between the evaluated pain measurement scale methods (p>0.05). Conventional retractors used in the acquisition of thermal images can interfere with the accuracy of the temperature value obtained. The development of a specific retractor for intraoral IT is necessary to acquire reliable data, as AM can facilitate the manufacture of parts that solve clinical problems, in addition to allowing better adaptation of the device to the oral cavity.
Palavras-chave: Odontologia
Termografia
Impressão 3D
Área(s) do CNPq: ODONTOLOGIA::CLINICA ODONTOLOGICA
Idioma: por
País: Brasil
Instituição: Universidade Estadual da Paraíba
Sigla da instituição: UEPB
Departamento: Pró-Reitoria de Pós-Graduação e Pesquisa - PRPGP
Programa: Programa de Pós-Graduação em Odontologia - PPGO
Citação: LOPES, Layrlla Kateriny Moura Oliveira. Desenvolvimento de um afastador labial para uso em exame termográfico da cavidade bucal. 2023. 119 p. Tese (Programa de Pós-Graduação em Odontologia - PPGO) - Universidade Estadual da Paraíba, Campina Grande, 2023.
Tipo de acesso: Acesso Embargado
URI: http://tede.bc.uepb.edu.br/jspui/handle/tede/4775
Data de defesa: 17-Ago-2023
Aparece nas coleções:PPGO - Teses

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
TS - Layrlla Kateriny Moura Oliveira Lopes.pdfTS - Layrlla Kateriny Moura Oliveira Lopes 3.31 MBAdobe PDFBaixar/Abrir Pré-Visualizar    Solictar uma cópia
Termo de depósito BDTD.pdfTermo de depósito BDTD155.16 kBAdobe PDFBaixar/Abrir Pré-Visualizar    Solictar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.