Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.bc.uepb.edu.br/jspui/handle/tede/4661
Tipo do documento: Dissertação
Título: Protótipo de posicionador craniano de eletrodos para estimulação transcraniana por corrente contínua de alta definição utilizando tecnologias 3D
Título(s) alternativo(s): Prototype of a cranial electrode positioner for high definition transcranial direct current stimulation using 3D technologies
Autor: Silva, Arthur Cellys Tavares da 
Primeiro orientador: Vasconcelos, Danilo de Almeida
Primeiro coorientador: Martins, Ketinlly Yasmyne Nascimento
Primeiro membro da banca: Farias, Kelly Soares
Segundo membro da banca: Branco, Rodolfo Ramos Castelo
Terceiro membro da banca: Vasconcelos, Danilo
Resumo: Introdução:Dentre as estratégias não-farmacológicas para tratamento da dor crônica a estimulação transcraniana por corrente contínua de alta definição (ETCC-HD) vem como estratégia bastante promissora, pois atua modulando de maneira focal a dor a nível cortical a partir da aplicação de corrente elétrica contínua no escalpo craniano. No contexto de fabricação de dispositivos para saúde, as tecnologias 3D, utilizando como base a Manufatura Aditiva se torna uma ferramenta acessível e inovadora no desenvolvimento deste dispositivo. A escolha da MA se deve pelo fato de ser uma tecnologia pouco utilizada na área em questão, possuir menor custo de mercado e permitir que seja desenvolvido o dispositivo de maneira acessível, prática e adaptável a necessidade de posicionamento para neuromodulação. Objetivo: desenvolver um dispositivo de posicionamento de eletrodos 4x1 para estimulaçãotranscraniana por corrente contínua de alta definição a partir de tecnologias 3D. Metodologia: Para desenvolvimento do dispositivo foram seguidas quatro etapas. Inicialmente foi realizada a captação digital da região de interesse a partir de escaneamento digital da cabeça/crânio de um indivíduo adulto. Na etapa seguinte, foi realizada a modelagem digital tridimensional a partir do software CAD e a definição da métrica de posicionamento a partir do sistema 10-20 do EEG para estimulação do córtex motor primário (M1). Na etapa de fabricação foi impresso o dispositivo de posicionamento de eletrodos e também um biomodelo do crânio/tecido mole do indivíduo escolhido para servir de modelo para testes do produto. Nessa etapa também foram criadas as ventosas que servirão de condutores da corrente elétrica para estimulação. Para a fabricação do biomodelo e também para o posicionador, a tecnologia escolhida foi FDM que é muito utilizada na criação de termoplásticos. O material utilizado para impressão foi o PLA que apresenta boa resistência e baixo custo. As ventosas foram fabricadas pela tecnologiaSLA, utilizando resina líquida como material. Por fim, houve avalidação do produto, que consistiu na realização de testes de funcionamento do dispositivo de acordo com os objetivos traçados para a fabricação.Resultados: de acordo com alguns estudos como o de VILLAMAR, M. F. et al (2013) é possível propor que utilização do anel 4x1 na estimulação transcraniana por corrente contínua se torna uma abordagem quefocaliza melhor a área de interesse e aumenta a duração dos efeitos. E para que essa fabricaçãofosse de menor custo e utilizasse um recurso tecnológico, usou-se a manufatura aditiva para sua fabricação, a qual está em ascensão no desenvovimento de produtos para saúde. (ISO/ASTM 52900: 2016). Conclusão: foi possível desenvolver e fabricar um protótipo de posicionador de eletrodos para estimulação transcraniana por corrente contínua de alta definição a partir da manufatura aditiva, tornando-o um dispositivo barato, de fácil manuseio, biodegradável e com possibilidades de aplicabilidade em pesquisas científicas de caráter clínico.
Abstract: Introduction: Among the non-pharmacological strategies for the treatment of chronic pain, high-definition transcranial direct current stimulation (HD-ETCC) is a very promising strategy, as it acts by focally modulating pain at the cortical level from the application of current continuous electrical current on the cranial scalp. In the context of manufacturing health devices, 3D technologies, using Additive Manufacturing as a basis, become an accessible and innovative tool in the development of this device. The choice of AM is due to the fact that it is a technology little used in the area in question, has a lower market cost and allows the device to be developed in an accessible, practical and adaptable way to the need for positioning for neuromodulation. Objective: to develop a 4x1 electrode positioning device for high-definition transcranial direct current stimulation using 3D technologies. Methodology: For the development of the device, four stages were followed. Initially, a digital capture of the region of interest was performed from a digital scan of the head/skull of an adult individual. In the next step, three-dimensional digital modeling was performed using the CAD software and the positioning metric was defined using the EEG 10-20 system for stimulation of the primary motor cortex (M1). During the manufacturing stage, the electrode positioning device was printed, as well as a biomodel of the skull/soft tissue of the individual chosen to serve as a model for testing the product. At this stage, the suction cups that will serve as conductors of the electrical current for stimulation were also created. For the manufacture of the biomodel and also for the positioner, the chosen technology was FDM, which is widely used in the creation of thermoplastics. The material used for printing was PLA, which has good resistance and low cost. The suction cups were manufactured by SLA technology, using liquid resin as material. Finally, there was a product evaluation, which consisted of carrying out device function tests according to the objectives outlined for manufacturing. Results: according to some studies such as VILLAMAR, M. F. et al (2013) it is possible to propose that The use of the 4x1 ring in transcranial direct current stimulation becomes an approach that better focuses the area of interest and increases the duration of effects. And for this manufacturing to be lower cost and use a technological resource, additive manufacturing was used for its manufacture, which is on the rise in the development of health products. (ISO/ASTM 52900: 2016). Conclusion: it was possible to develop and manufacture an electrode positioner prototype for high-definition transcranial direct current stimulation using additive manufacturing, making it a cheap, easy-to-handle, biodegradable device with possibilities of applicability in scientific research. clinical.
Palavras-chave: Dor crônica
Estimulação Transcraniana por Corrente Contínua
Impressão Tridimensional
Three Dimensional Printing
Transcranial Direct Current Stimulation
Chronic pain
Área(s) do CNPq: ENGENHARIA BIOMEDICA::BIOENGENHARIA
CIENCIAS DA SAUDE
Idioma: por
País: Brasil
Instituição: Universidade Estadual da Paraíba
Sigla da instituição: UEPB
Departamento: Pró-Reitoria de Pós-Graduação e Pesquisa - PRPGP
Programa: Programa de Pós-Graduação Profissional em Ciência e Tecnologia em Saúde - PPGCTS
Citação: SILVA, Arthur Cellys Tavares da. Protótipo de posicionador craniano de eletrodos para estimulação transcraniana por corrente contínua de alta definição utilizando tecnologias 3D. 2022. 45f. Dissertação (Programa de Pós-Graduação Profissional em Ciência e Tecnologia em Saúde - PPGCTS) - Universidade Estadual da Paraíba, Campina Grande - PB, 2027.
Tipo de acesso: Acesso Embargado
URI: http://tede.bc.uepb.edu.br/jspui/handle/tede/4661
Data de defesa: 28-Nov-2022
Aparece nas coleções:PPGCTS - Dissertações

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DS - Arthur Cellys Tavares da Silva.pdfDS - Arthur Cellys Tavares da Silva2.23 MBAdobe PDFBaixar/Abrir Pré-Visualizar    Solictar uma cópia
Termo de depósito BDTD.pdfTermo de Depósito BDTD2.4 MBAdobe PDFBaixar/Abrir Pré-Visualizar    Solictar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.