Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.bc.uepb.edu.br/jspui/handle/tede/3519
Registro completo de metadados
Campo DCValorIdioma
dc.creatorVieira, Luiz Eduardo Marinho-
dc.creator.Latteshttp://lattes.cnpq.br/3096763371621530por
dc.contributor.advisor1Melo, Daniela Pita de-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2824485698432887por
dc.contributor.referee1Campos, Paulo Sérgio Flores-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/9695030339751842por
dc.contributor.referee2Alves, Pollianna Muniz-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/4860117599607892por
dc.date.accessioned2019-10-10T17:45:54Z-
dc.date.issued2019-06-05-
dc.identifier.citationVIEIRA, L. E. M. Avaliação da influência de diferentes materiais intracanais na detecção de fraturas radiculares em dentes birradiculares por meio de TCFC. 2019. 72f. Dissertação (Programa de Pós-Graduação em Odontologia - PPGO) - Universidade Estadual da Paraíba, Campina Grande, 2019.por
dc.identifier.urihttp://tede.bc.uepb.edu.br/jspui/handle/tede/3519-
dc.description.resumoO objetivo deste estudo foi avaliar a precisão de imagens geradas por dois sistemas tomografia computadorizada de feixe cônico (TCFC) na detecção de fraturas radiculares verticais (FRVs) artificialmente induzidas e a presença de artefatos em dentes birradiculares restaurados com diferentes materiais intracanais. Métodos: A amostra consistiu em vinte pré- molares birradiculares. Fratura radicular foi induzida na raiz lingual de metade da amostra. Sete combinações de material intracanal foram introduzidas passivamente na amostra: vazio; gutta-percha; raíz vestibular com gutta-percha e raiz lingual com pino de fibra de vidro; raiz vestibular com gutta-percha e raiz lingual com pino de fibra de vidro com filete metálico; pinos de fibra de vidro; pinos de fibra de vidro com filete metálico e pinos de NiCr. A amostra foi escaneada utilizando dois aparelhos de TCFC, CS 9000 e OP300. Os parâmetros de exposição foram fixados em 90kV e 8mA. Voxel e FOV foram fixados em 0,085mm e 5x5cm para OP300 e 0,076mm e 5x3,75cm para CS 9000. Dois observadores avaliaram todas as imagens utilizando uma escala de confiança de 5 pontos para detecção de fratura e uma escala de 4 pontos para a presença de artefatos. A sensibilidade, especificidade, acurácia e área sob a curva ROC foram comparadas por ANOVA two-way e teste de Tukey. A formação de artefatos foi avaliada por estatística descritiva e Qui-quadrado. Resultados: Não houve diferença significativa entre os materiais intracanais e entre os sistem as CBCT para sensibilidade, acurácia e área sob a curva ROC. Houve diferenças significativas entre os scanners (P = 0,008) e entre os diferentes grupos de materiais intracanais, quando o mesmo scanner foi considerado (P <0,001) para especificidade. O grupo pino de NiCr mostrou presença severa de artefato em todas as imagens. Conclusões: O CS 9000 3D apresentou melhor desempenho que o OP300 na detecção de fraturas radiculares verticais. Dentes não restaurados e dentes preenchidos com pinos de fibra de vidro foram considerados os grupos com menor interferência de artefatos e melhores resultados de detecção de FRV.por
dc.description.abstractAim: The aim of this study was to evaluate the precision of images generated by two CBCT systems on the detection of artificially induced vertical root fractures (VRF) and artifact intensity using birooted teeth restored with different intracanal materials. Methods: The sample consisted of 20 extracted birooted premolars. Root fracture was induced in half of the sample. Seven root filling combinations were used in each tooth: unrestored, gutta -percha, a buccal root with gutta-percha and a lingual root with a fiberglass post, a buccal root with gutta-percha and a lingual root with a metal core fiberglass post, fiberglass posts, metal core fiberglass posts, and NiCr posts. CBCT scans were acquired using CS 9000 and OP300 units. Exposure parameters were fixed at 90kV and 8mA. Voxel and FOV were set at 0.085mm and 5x5cm for OP300 and 0.076mm and 5x3.75cm for CS 9000. Two observers assessed all images using a 5-point confidence scale for fracture detection and a 4-point score for artifact interference. Sensitivity, specificity, accuracy and AUC were compared by two -way ANOVA and Tukey test. Artefact interference was evaluated by descriptive statistics and Chi-square test. Results: There was no significant difference between intracanal materials and CBCT scanners for sensibility, accuracy and AUC values. There were significant differences between scanners (P = 0.008) and among the different intracanal material groups (OP300) (p <0.001) for specificity. Metal post + Metal post group showed severe artifact interference in all images. Conclusions: In summary, CS 9000 3D presented better performance than OP300 on vertical root fracture detection of endodontically treated teeth. Unrestored teeth and teeth filled with fiberglass posts were considered the groups with lowest artifact interference and highest VRF detection results.eng
dc.description.provenanceSubmitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2019-10-10T17:39:11Z No. of bitstreams: 1 PDF - Luiz Eduardo Marinho Vieira.pdf: 2286485 bytes, checksum: 884a1b442f2465f8043ef85393aeb26b (MD5)eng
dc.description.provenanceApproved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2019-10-10T17:45:54Z (GMT) No. of bitstreams: 1 PDF - Luiz Eduardo Marinho Vieira.pdf: 2286485 bytes, checksum: 884a1b442f2465f8043ef85393aeb26b (MD5)eng
dc.description.provenanceMade available in DSpace on 2019-10-10T17:45:54Z (GMT). No. of bitstreams: 1 PDF - Luiz Eduardo Marinho Vieira.pdf: 2286485 bytes, checksum: 884a1b442f2465f8043ef85393aeb26b (MD5) Previous issue date: 2019-06-05eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://tede.bc.uepb.edu.br/jspui/retrieve/8834/PDF%20-%20Luiz%20Eduardo%20Marinho%20Vieira.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade Estadual da Paraíbapor
dc.publisher.departmentPró-Reitoria de Pós-Graduação e Pesquisa - PRPGPpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUEPBpor
dc.publisher.programPrograma de Pós-Graduação em Odontologia - PPGOpor
dc.rightsAcesso Abertopor
dc.subjectFratura radicularpor
dc.subjectTomografia computadorizada de feixe cônicopor
dc.subjectRaiz dentáriapor
dc.subjectDente pré-molarpor
dc.subjectCone-beam computed tomographyeng
dc.subjectTooth Rooteng
dc.subjectPremolareng
dc.subject.cnpqCIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleAvaliação da influência de diferentes materiais intracanais na detecção de fraturas radiculares em dentes birradiculares por meio de TCFCpor
dc.typeDissertaçãopor
Aparece nas coleções:PPGO - Dissertações

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
PDF - Luiz Eduardo Marinho Vieira.pdfPDF - Luiz Eduardo Marinho Vieira2.23 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.