Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.bc.uepb.edu.br/jspui/handle/tede/3511
Registro completo de metadados
Campo DCValorIdioma
dc.creatorPeixoto, Larissa Rangel-
dc.creator.Latteshttp://lattes.cnpq.br/4194623340602725por
dc.contributor.advisor1Melo, Daniela Pita de-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2824485698432887por
dc.contributor.referee1Bento, Patrícia Meira-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/7371238765825611por
dc.contributor.referee2Melo, Saulo Leonardo Sousa-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/3043966507619496por
dc.contributor.referee3Oliveira, Matheus Lima de-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/3156969817236677por
dc.contributor.referee4Cavalcanti, Yuri Wanderley-
dc.contributor.referee4Latteshttp://lattes.cnpq.br/1303695205442802por
dc.date.accessioned2019-10-10T14:14:48Z-
dc.date.issued2019-07-22-
dc.identifier.citationPEIXOTO, L. R. Influência de diferentes técnicas de cimentação de pinos de fibra de vidro na resistência à fratura, detecção de trincas e geração de artefatos em pré-molares unirradiculares. 2019. 107f. Tese (Programa de Pós-Graduação em Odontologia - PPGO) - Universidade Estadual da Paraíba, Campina Grande, 2019.por
dc.identifier.urihttp://tede.bc.uepb.edu.br/jspui/handle/tede/3511-
dc.description.resumoObjetivos: Avaliar a influência de diferentes técnicas de cimentação de pinos de fibra de vidro (PFV) na resistência à fratura radicular, potencial de detecção de trincas e geração de artefatos tomográficos e microtomográficos. Metodologia: Quarenta dentes pré-molares unirradiculares foram divididos aleatoriamente em quatro grupos (n = 10): FGA- PFV cimentado com cimento resinoso dual; FGCore- PFV cimentado com cimento resinoso dual com alto conteúdo de carga; MCFG- PFV com filamento metálico cimentado com cimento resinoso dual; AFG – PFV anatomizado cimentado com cimento resinoso dual. Cada dente foi submetido ao teste de resistência à fratura a 0,5mm/min em uma máquina universal de testes (ISTRON 3365 Machine). A amostra foi escaneada no Skyscan 1172 (Bruker, Kontich, Bélgica) para avaliar a morfologia inicial dos dentes e o padrão de fratura, utilizando os seguintes escores: (1) fratura do núcleo de preenchimento; (2) fratura radicular favorável; e (3) fratura radicular desfavorável. Além disso, foi realizada uma quantificação da porcentagem de artefatos gerados em imagens de Micro-Tomografia Computadorizada (Micro-TC). As imagens de Tomografia Computadorizada de Feixe Cônico (TCFC) foram adquiridas usando o CS 9000 3D (Kodak Dental Systems, Carestream Health, Rochester, NY, EUA). Cada dente foi escaneado sob quatro parâmetros de exposição: 74kV, 80kV, 85kV e 90kV. Os demais parâmetros foram fixados em 76 µm de tamanho de voxel, 5 cm x 3,75 cm de tamanho de FOV e 10 mA. Dois observadores avaliaram as imagens de TCFC para detecção de fratura radicular utilizando uma escala de confiança de 5 pontos e um escore de 4 pontos para a presença de artefatos. A análise de variância unidirecional (ANOVA) e o teste de Tukey foram utilizados para verificar os valores de resistência a fratura entre os grupos, enquanto o teste exato de Fisher foi usado para averiguar a associação entre o padrão de fratura e os grupos. A avaliação quantitativa de artefatos de Micro-TC foi analisada usando os testes de Kruskall Wallis e Mann Whitney. Os valores de sensibilidade, especificidade e área sob a curva ROC (AUC) foram calculados e comparados por análises de variância bidirecional (ANOVA two-way) e teste de Tukey. A interferência dos artefatos no diagnóstico de fratura radicular foi avaliada pelo teste do qui-quadrado. Os dados foram tratados estatisticamente ao nível de significância de 5% (α = 0,05). Resultados: Os valores de resistência à fratura radicular variaram de 465,38 ± 127,29 N a 364,47 ± 78,64 N (p = 0,159). Não foi observada associação estatisticamente significante entre o padrão de fratura e as técnicas de cimentação de PFV (p = 0,276). A quantificação de artefatos de imagem de Micro-TC para todos os grupos apresentou menos de 10% de artefatos (p = 0,062). Não houve diferenças significativas entre os parâmetros de exposição para sensibilidade, especificidade e valores de AUC (p> 0,05). O grupo AFG apresentou maiores valores de sensibilidade, diferindo estatisticamente do FGCore e do MCFG (p = 0,037). Os valores de especificidade do MCFG diferiram estatisticamente do FGCore (p = 0,012), apresentando menores valores. O grupo MCFG apresentou maior porcentagem de artefatos do que os demais grupos estudados (p <0,001). Conclusões: As diferentes técnicas de cimentação de PFV não influenciaram na resistência à fratura, no padrão de fratura e na intensidade de artefatos de Micro-CT. Diferentes parâmetros de exposição não interferem na detecção de fraturas radiculares. A presença do filamento metálico no interior do PFV diminui os valores de especificidade de fratura radicular e aumentou a intensidade do artefato em imagens de TCFC.por
dc.description.abstractObjectives: To evaluate the influence of different fiberglass post (FGP) cementation techniques on root fracture resistance, crack detection potential and generation of tomographic and microtomographic artifacts. Methodology: Forty single-rooted human premolars teeth were randomly divided into four groups (n=10): FGA- Fiberglass post cemented with dual-curing resin cement; FGCore- Fiberglass post cemented with dual-curing resin cement with high filler content; MCFG- Metal core fiberglass post cemented with dual- curing resin cement; AFG- Anatomical fiberglass post cemented with dual-curing resin cement. Each tooth was submitted to fracture resistance test at 0.5mm/min in a universal testing machine (ISTRON 3365 Machine). Then, all teeth were scanned on Skyscan 1172 to assess initial tooth morphology and fracture pattern using the following scores: (1) Fracture of the coronal composite resin; (2) Favorable root fracture; and (3) Unfavorable root fracture. In addition, a quantification of the percentage of artifacts generated in Computed Micro- Tomography (Micro-CT) images was performed. Cone-Beam Computed Tomography (CBCT) images were acquired using the CS 9000 3D (Kodak Dental Systems, Carestream Health, Rochester, NY, USA). Each tooth was scanned under four exposure parameters: 74kV, 80kV, 85kV and 90kV. The other parameters were set at 76 µm voxel size, 5 cm x 3.75 cm FOV size and 10 mA. Two observers assessed all CBCT images for root fracture detection using a 5-point confidence scale and a 4-point score for the presence of artifacts. One-way analysis of variance (ANOVA) and Tukey test were used to verify fracture resistance values between groups, while Fisher's exact test was used to verify the association between fracture pattern and groups. Quantitative evaluation of Micro-TC artifacts was analyzed using Kruskall Wallis and Mann Whitney tests. Sensitivity, specificity and area under the ROC curve (AUC) values were calculated and compared by two-way analyses of variance (ANOVA two-way) and Tukey's test Artifact interference on root fracture was assessed by chi-square test. Data were treated statistically at significance level of 5% ( α=0.05). Results: Fracture resistance values varied from 465,38 ± 127,29 N to 364,47 ± 78,64 N (p=0.159). No association between the fracture pattern and fiberglass cementation techniques was observed (p=0.276). The quantification of Micro-CT image artifacts for all groups presented less than 10% of artifacts (p=0,062). There were no significant differences between the exposure parameters for sensitivity, specificity and AUC values (p>0.05). AFG presented higher sensitivity values, statistically differing from FGCore and MCFG (p=0.037). MCFG specificity values differed statistically from FGCore (p=0.012). MCFG presented higher percentage of moderate artifacts than the other studied groups (p=0.001). Conclusions: Fiberglass cementation techniques did not influence the resistance, fracture pattern, and Micro-CT artifact intensity. Different exposure parameters do not seem to interfere on root fracture detection. The presence of a metal core fiberglass post decreases root fracture detection specificity values and increases artifact intensity in CBCT images.eng
dc.description.provenanceSubmitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2019-09-30T12:36:06Z No. of bitstreams: 1 PDF - Larissa Rangel Peixoto.pdf: 2424939 bytes, checksum: 8270b91e164211743eee1a7224fe7822 (MD5)eng
dc.description.provenanceApproved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2019-10-10T14:14:48Z (GMT) No. of bitstreams: 1 PDF - Larissa Rangel Peixoto.pdf: 2424939 bytes, checksum: 8270b91e164211743eee1a7224fe7822 (MD5)eng
dc.description.provenanceMade available in DSpace on 2019-10-10T14:14:48Z (GMT). No. of bitstreams: 1 PDF - Larissa Rangel Peixoto.pdf: 2424939 bytes, checksum: 8270b91e164211743eee1a7224fe7822 (MD5) Previous issue date: 2019-07-22eng
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://tede.bc.uepb.edu.br/jspui/retrieve/8862/PDF%20-%20Larissa%20Rangel%20Peixoto.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade Estadual da Paraíbapor
dc.publisher.departmentPró-Reitoria de Pós-Graduação e Pesquisa - PRPGPpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUEPBpor
dc.publisher.programPrograma de Pós-Graduação em Odontologia - PPGOpor
dc.rightsAcesso Abertopor
dc.subjectPinos de fibra de vidropor
dc.subjectArtefatospor
dc.subjectTomografia Computadorizada de Feixe Cônicopor
dc.subjectArtifactseng
dc.subjectCone-Beam Computed Tomographyeng
dc.subjectFiberglasseng
dc.subject.cnpqCIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleInfluência de diferentes técnicas de cimentação de pinos de fibra de vidro na resistência à fratura, detecção de trincas e geração de artefatos em pré-molares unirradicularespor
dc.typeTesepor
Aparece nas coleções:PPGO - Teses

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
PDF - Larissa Rangel Peixoto.pdfPDF - Larissa Rangel Peixoto2.37 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.