Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
http://tede.bc.uepb.edu.br/jspui/handle/tede/3252
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Siqueira, Gustavo Lopes Gomes de | - |
dc.creator.Lattes | http://lattes.cnpq.br/3088841234476693 | por |
dc.contributor.advisor1 | Sousa, Robson Pequeno de | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/3300067187001570 | por |
dc.contributor.referee1 | Almeida, Carlos Wilson Dantas de | - |
dc.contributor.referee1Lattes | http://lattes.cnpq.br/5827398788235627 | por |
dc.contributor.referee2 | Engelhorn, Carlos Alberto | - |
dc.contributor.referee2Lattes | http://lattes.cnpq.br/7551583711429844 | por |
dc.date.accessioned | 2019-03-27T18:39:40Z | - |
dc.date.issued | 2018-10-18 | - |
dc.identifier.citation | SIQUEIRA, G. L. G. de. Caracterização tecidual ultrassonográfica renal (CATUS): Análise comparativa entre tons de cinza de imagens renais após padronização de sua aquisição – Proposição de um método diagnóstico auxiliado por computador (CAD). 2018. 81f. Dissertação (Programa de Pós-Graduação Profissional em Ciência e Tecnologia em Saúde - PPGCTS) - Universidade Estadual da Paraíba, Campina Grande, 2018. | por |
dc.identifier.uri | http://tede.bc.uepb.edu.br/jspui/handle/tede/3252 | - |
dc.description.resumo | A avaliação da ecodensidade renal através da ultrassonografia permanece a mesma desde seu advento nos anos 80. Como as imagens ultrassonográficas são obtidas em 256 tons de cinza e capacidade do ser humano de percebe-la é limitada à 32 tons, faz-se uso de sistemas computacionais inteligentes do tipo Diagnostico Assistido por Computador-CAD, que auxiliam o especialista na análise da intensa variabilidade de cinza nas imagens. Neste sentido, foi realizada uma investigação com 24 pacientes, ponderando quatro tipos de imagens ultrassonográficas renais de acordo com sua aquisição e processamento, obtidas por cinco especialistas e dois tipos de aparelhos de ultrassonografia. Foi desenvolvido um protótipo de software cujo objetivo foi determinar a mediana de escala de cinza (GSM) e diferentes intervalos de tons de cinza representantes de tecidos histológicos virtuais, auxiliando a identificação da variabilidade da imagem renal ultrassonográfica e verificando a possibilidade de um CAD que auxilie um possível diagnóstico baseado na análise dos tons de cinza . Os resultados mostraram que a GSM de imagens renais de um mesmo paciente, obtidas por dois tipos de aparelhos, são estatisticamente diferentes. Foram analisados quatro tipos de imagens, partindo de uma totalmente aleatória (sem qualquer padronização na sua aquisição), uma padronizada (fixado o ganho, TGC e dynamic range), e essas duas passando por um processo de normatização já descrito na literatura e comparando-as com as imagens adquiridas por três médicos diferentes. Resultou-se que a imagem aleatória, de acordo com o teste de Wilcoxon- Mann-Whitney difere estatisticamente entre os profissionais, mesmo passando pelo processo de normatização. A imagem padronizada, após passar pelo processo de normatização, apresenta resultados equivalentes entre os três médicos, não possuindo diferença estatística. Constatou-se que a análise de tons de cinza, para ser utilizada em um CAD e comparada com diferentes profissionais, deve ser adquirida por um mesmo tipo de máquina ultrassonográfica e utilizando uma imagem em que sejam padronizados aspectos físicos, e após passando por um processo de normatização. | por |
dc.description.abstract | The evaluation of the renal ecodensity through ultrasound remains the same since its advent. As the ultrasound images are obtained in 256 shades of gray and the human being capacity of perceiving it is limited to 32 shades, it is made usage of intelligent computer systems of Computer-Assisted Diagnosis (CAD) kind which assist the expert in the analysis of the intense variability of gray in the images. Following this sense, an investigation was performed using 24 patients, pondering four types of renal sonographic images according to their acquisition and processing, obtained by five specialists and two types of ultrasound equipment. A software prototype was developed whose objective was to determine the gray scale median (GSM) and different intervals of gray tones representing virtual histological tissues, helping the identification of the variability of the renal sonographic image and verifying the possibility of a CAD that helps in a possible diagnosis based on the gray-scale analysis. The results showed that the GSM of renal images of the same patient, obtained by two different types of devices, are statistically different. Four types of images were analyzed, from a totally random one (without any standardization in their acquisition), to a standardized one (fixed the gain, TGC and dynamic range), and these two going through a normalization process already described in the literature and comparing them with the images acquired by three different physicians. It was found that the random image, according to the Wilcoxon- Mann-Whitney test, differs statistically among the professionals, even passing through the normalization process. The standardized image, after passing through the normalization process, presents equivalent results among the three physicians, not having statistical difference. It was verified that the gray scale analysis, to be used in a CAD and compared with different professionals, must be acquired by a same type of ultrasound machine and using an image in which physical aspects are standardized, and after that, passing through a process of standardization. | eng |
dc.description.provenance | Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2019-03-25T16:22:34Z No. of bitstreams: 1 PDF - Gustado Lopes Gomes de Siqueira.pdf: 25379849 bytes, checksum: f850f37daa7fe8ee84565024da0c014f (MD5) | eng |
dc.description.provenance | Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2019-03-27T18:39:40Z (GMT) No. of bitstreams: 1 PDF - Gustado Lopes Gomes de Siqueira.pdf: 25379849 bytes, checksum: f850f37daa7fe8ee84565024da0c014f (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2019-03-27T18:39:40Z (GMT). No. of bitstreams: 1 PDF - Gustado Lopes Gomes de Siqueira.pdf: 25379849 bytes, checksum: f850f37daa7fe8ee84565024da0c014f (MD5) Previous issue date: 2018-10-18 | eng |
dc.format | application/pdf | * |
dc.thumbnail.url | http://tede.bc.uepb.edu.br/jspui/retrieve/7899/PDF%20-%20Gustado%20Lopes%20Gomes%20de%20Siqueira.pdf.jpg | * |
dc.language | por | por |
dc.publisher | Universidade Estadual da Paraíba | por |
dc.publisher.department | Pró-Reitoria de Pós-Graduação e Pesquisa - PRPGP | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | UEPB | por |
dc.publisher.program | Programa de Pós-Graduação Profissional em Ciência e Tecnologia em Saúde - PPGCTS | por |
dc.rights | Acesso Aberto | por |
dc.subject | Imagem ultrassonográfica | por |
dc.subject | Diagnóstico Auxiliado por Computador - CAD | por |
dc.subject | Mediana de Escala de Cinza | por |
dc.subject | Computer Aided Diagnosis | eng |
dc.subject | Gray Scale Median | eng |
dc.subject.cnpq | CIENCIAS DA SAUDE::MEDICINA | por |
dc.title | Caracterização tecidual ultrassonográfica renal (CATUS): Análise comparativa entre tons de cinza de imagens renais após padronização de sua aquisição – Proposição de um método diagnóstico auxiliado por computador (CAD) | por |
dc.type | Dissertação | por |
Aparece nas coleções: | PPGCTS - Dissertações |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
PDF - Gustado Lopes Gomes de Siqueira.pdf | PDF - Gustado Lopes Gomes de Siqueira | 24.79 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.